HR-1024i

When your research needs the best, full-range, field portable spectroradiometer then you want the HR-1024i.  The exceptional spectral resolution, optical quality, and low noise ensure that the collected data is of the highest quality.

HR-1024i Specifications

Spectral Range350 nm – 2500 nm
Internal Memory1000 scans
Channels1024
Linear Array(1) 512ch Si, 350 – 1000 nm
(1) 256ch InGaAs, 1000 – 1890 nm
(1) 256ch Extended InGaAs, 1890 – 2500 nm
Spectral Resolution (FWHM)3.3 nm, 700 nm
9.5 nm, 1500 nm
6.5 nm, 2100 nm
Bandwidth (nominal)1.5 nm, 350 – 1000 nm
3.8 nm, 1000 – 1890 nm
2.5 nm, 1890 – 2500 nm
Minimum Integration1 millisecond
FOV4˚ standard, 8˚ or 14˚ optional
25˚ optional armored fiber optic
Noise Equivalent Radiance
≤ 0.8 x 10-9 W/cm2/nm/sr @ 700 nm
≤ 1.2 x 10-9 W/cm2/nm/sr @ 1500 nm
≤ 1.2 x 10-9 W/cm2/nm/sr @ 2100 nm
Stand Alone Measurements
(no computer required)
Standard
Calibration Accuracy
(NIST Traceable)
±5% @ 400 nm
±4% @ 700 nm
±7% @ 2200 nm
Wavelength Reproducibility0.1 nm
Dark Current CorrectionAutomatic
Spectrum AveragingAutomatic/selectable
Internal Digital CameraSupplied
Internal GPSSupplied

Physical Specifications

Head Size8.75” x 11.5” x 3.0”
Weight8.5lbs., 3.8kg
Host Communications InterfaceWireless Bluetooth
USB
RS232
SealingSealed against dirt and dust
Tripod mountingStandard 1/4-20 camera mounts
Battery Type7.4 V lithium ion
Battery Life3 hours approximately
SightingLaser diode

HR-1024i Details

Designed for maximum optical performance the SVC HR-1024i has:

  • Co-aligned symmetrical and uniform field of view
  • Full conical field of view eliminating spectral discontinuities and step discontinuities at the spectrometer sensor interfaces
    • Conical field of view gives better measurement data for all surfaces, especially heterogeneous surfaces

Sample Scans

Features

And the HR-1024i delivers the highest quality data with industry leading ease of use:

  • Data stored in the built-in computer – no external computer to carry in the field

  • Scene photos and GPS coordinates stored with every file, so you know exactly what the conditions were for each scan

  • Two Bluetooth devices allow the instrument to receive data from an external sensor suite containing up to 16 separate sensors. The sensor suite can include downwelling sensors supplying instantaneous broad or narrow band solar response. The sensor data is stored with the spectral data file, allowing the researcher to understand changes in solar irradiance and assist in corrections

  • Other environmental sensors are available.

maximize your time in the field

Download Our Free Field Spectroscopy Guide